Free template
Workplace safety inspection checklist: free and printable
This free workplace safety inspection checklist is a walkthrough form for a general industry workplace such as a plant, shop or warehouse. Check each item, write down what you find, and give every problem an owner and a due date in the corrective action table.
How do you use this template?
- Adapt it first. Strike out items that do not apply to the area and add checks for your own equipment and hazards.
- Walk the area during normal work, not after hours, and talk to the employees who work there.
- Mark each item Yes, No or N/A, and use the notes column for where and what.
- Turn every No into a finding in the table at the end, with its location.
- Give each finding a corrective action, an owner and a due date, and fix anything immediately dangerous before you move on.
- Follow up until every finding is closed, and keep the completed sheet with your safety records.
Workplace safety inspection
Free template from Featherstone Safety Hub, featherstonesafetyhub.com. General information, not legal advice.
Area or site inspected:
Inspected by:
Date:
Time and shift:
Employees spoken to:
Supervisor of the area:
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Floors clean, dry and free of trip hazards | ||||
| Aisles and passageways clear, and marked where forklifts operate | ||||
| Open sides, platforms and floor openings guarded or covered | ||||
| Portable ladders in good condition, with no broken rungs or rails | ||||
| Stairs have handrails and are not used for storage |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Exit routes and exit doors unobstructed and unlocked from the inside | ||||
| Exit signs visible and lit | ||||
| Evacuation map or emergency action plan available in the area | ||||
| Alarm can be heard in the area | ||||
| First aid kit and eyewash stocked and reachable |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Portable fire extinguishers in place, unobstructed and charged | ||||
| Monthly visual inspection recorded on each extinguisher | ||||
| Flammable liquids kept in approved containers or cabinets, away from ignition sources | ||||
| Combustible waste removed regularly |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Electrical panels accessible, with clear space in front | ||||
| No damaged cords, missing covers or open knockouts | ||||
| Extension cords not used in place of permanent wiring | ||||
| Ground-fault protection where cords and tools are used in wet locations |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Guards in place on points of operation, belts, pulleys, chains and rotating parts | ||||
| Emergency stops work and can be reached | ||||
| Lockout devices and machine-specific procedures available | ||||
| Equipment that is out of service is tagged or locked out |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Every container labeled, including containers chemicals were transferred into | ||||
| Safety data sheets available for the chemicals in this area | ||||
| Incompatible chemicals stored apart | ||||
| Spill kit available and stocked |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Required PPE for the area is posted or known to employees | ||||
| PPE in good condition and being worn | ||||
| Hearing protection worn where it is required |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| Forklift examination recorded for this shift or day | ||||
| Loads stacked stable, and racking undamaged | ||||
| Pedestrian routes separated from forklift routes or clearly marked |
| Check | Yes | No | N/A | Notes |
|---|---|---|---|---|
| OSHA Job Safety and Health poster displayed | ||||
| Form 300A annual summary posted from February 1 to April 30 (if you keep OSHA injury records) |
Findings and corrective actions
| # | Finding | Location | Corrective action | Owner | Due date | Done |
|---|---|---|---|---|---|---|
| 1 | ||||||
| 2 | ||||||
| 3 | ||||||
| 4 | ||||||
| 5 | ||||||
| 6 | ||||||
| 7 | ||||||
| 8 |
Inspector signature:
Reviewed by (supervisor or manager):
What OSHA requires
- Good practiceA general walkthrough checklist like this one is good practice. It is not an OSHA form, and no single federal rule requires it for general industry.
- OSHA requiresPortable fire extinguishers get a monthly visual inspection and an annual maintenance check (29 CFR 1910.157(e)(2) and (e)(3)).
- OSHA requiresForklifts and other powered industrial trucks are examined at least daily before being placed in service (29 CFR 1910.178(q)(7)).
- OSHA requiresIn construction, programs must provide for frequent and regular inspections of job sites, materials and equipment by competent persons designated by the employer (29 CFR 1926.20(b)(2)).
These are federal requirements; a State Plan may be stricter. Read more in What are an employer's responsibilities under the OSH Act?.
This template is general information for employers, last reviewed on November 26, 2026. It is not legal advice and not an OSHA form, and it is not published, approved or endorsed by OSHA or any agency. Adapt it to your own workplace.